PROTECTIVE COVERS
Flat covers, typically made of glass, are the easiest way to protect a luminaire against environmental elements. A flat shape, unfortunately, has some downside as it decreases the efficiency of the luminaire and slightly changes the light distribution. The transmission percentage of light perpendicular to the cover is close to 100% but decreases when the angle gets wider. On 70° angle the light transmission can drop to 60% or even lower. It is possible to increase the light transmission by adding antireflective coating on the flat cover, but this can be an expensive and time-consuming secondary process. Spherical covers have better efficiency than flat covers. The curved shape helps to increase light transmission percentage as the contact angle between the spherical cover and the rays of light at wider angles is less than with a flat cover. This means it is easier to create luminaires with really wide light distribution when using spherical covers. Spherical covers with constant thickness have only a slight effect on the light distribution of the luminaire. Uneven thickness, however, can have a major effect on the light distribution and performance of the luminaire
GLARE SHIELDING
Fixtures that produce very wide beam angles – which are common in many roadway lighting applications – tend to emit light above 75° angle. This causes glare, which is visually distracting and can lead to unsafe conditions for motor vehicle operators, so it is best that the fixture design limits or eliminates the amount of light above 75° angle. The easiest way to manage glare is to add a casing around the lenses. When the casing walls are higher than the secondary lenses, there will be no light above 90° angle and the amount of light at 75°-90° angles is greatly decreased. Casing with low reflectivity will have an impact on the efficiency of the luminaire so it is always best to use materials with high reflectivity within the luminaire casing. Flat, transparent covers are often used to protect the luminaire against environmental elements and also to reduce glare. Since a higher percentage of light is reflected back into the luminaire at wider emitting angles, the amount of light that leaves the fixture over 75° angle is reduced and so is glare from the luminaire. Flat covers are also the easiest method to eliminate uplight, in order to meet International Dark-Sky1 and other standards in many countries and local municipalities.
| Example setup | Efficienct | 80-90 | IESNA type | IESNA cutoff | Lav [cd/m2] | U0U | I | TI[%]S | R |
|---|---|---|---|---|---|---|---|---|---|
| Strada-2×2-DNW | 94.2%9 | .1 % | Type IV, medium | noncutoff | .150 | .4 | 0.72 | 20 | .6 |
| Strada-2×2-DNW, reflective walls(specular) | 93.3 % 1 | .3 % | Type III, medium | semi cutoff 1 | .150 | .4 | 0.61 | 40 | .6 |
| Strada-2×2-DNW, reflectove walls(diffusive) | 92.8 % 2 | .1 | Type III, shorts | semi cutoff1 | .080 | .4 | 0.61 | 30 | .6 |
| Strada-2×2-DNW, reflective walls (specular), 3mm flat PC or glass cover | 85.7 % | 2.% | Type III, medium | semi cutoff1 | .010 | .4 | 0.71 | 30 | .6 |
| Strada-2×2-DNW, reflective walls (diffusive), 3mm flat PC or glass cover | 87.5% | 1.6% | Type III, shortc | cutoff0 | .960 | .4 | 0.61 | 00 | .6 |